Notes to Upright Capacities
• Capacity is based on 36″ vertical beam spacing; Larger spacing decreases capacity.
• Capacities based upon interior usage.
• Capacities are for selective rack only.
• Capacities are for non-seismic usage.
• All columns/posts must be anchored to an adequate concrete floor (required by RMI code)
• Capacities based upon installation in plumb condition.
• Capacities are total per upright, assuming equal loading on both posts.
• Stainless steel anchors required for outdoor storage
If any of these conditions do not apply to your application, or if you are unsure if they apply, DO NOT USE THESE CAPACITY RATINGS. In those cases, contact Steel King’s Engineering department for design information.
NOTE: A Permit and/or stamped calculations may be required by the local building department prior to installation and is the responsibility of the end user. Rack is for indoor use only. If rack needs to be located outside contact Steel King for assistance. Rack is for non-seismic usage only. If rack is located in a seismic area, please consider the racking designed for Seismic Considerations or contact Steel King for assistance.